A comprehensive overview of Nader's low-voltage electrical product lines, covering miniature circuit breakers (MCBs), molded case circuit breakers (MCCBs), air circuit breakers (ACBs), surge protection devices (SPDs), industrial control components, intelligent distribution systems, and more. It categorizes products by function and series, offering technical highlights and typical applications, serving as a useful reference for distributors, engineers, and industrial users.
1.MCB(Miniature Circuit Breaker)
 |
 |
 |
NDB1 Series Circuit Breaker
|
NDM2LM-40 Electromagnetic residual current action circuit breaker |
NDB3-30, 50, 100 series equipment circuit breaker |
Series |
Design Series |
Product Features |
NDB1 |
NDB1-32/40/63/125 |
For full range of 32 shell frame,Icn=4,5kA ;
For full range of 40 and 63 shell frame,Icn=6kA;
For full range of 125 shell frame,Icn=10kA. |
NDB1T-63 |
Comply with GB14048.2 standard |
NDB1L-32 |
One-piece leakage, width:36mm |
NDB1PT-63 |
MCB for metering circuits; single magnetic type; maximum current: 10A. |
NDB1GQ-63 |
MCB with Overvoltage and undervoltage protection |
NDB1LG-32 |
Leakage MCB with overvoltage protection
|
NDB1LE-32/40/63/100 |
MCB with leakage protection; MCB for 32 and 40 shell frame are optional in A and AC types; MCB for 63 shell frame are optional in A, AC and B types; The width of 32 shell holder is only 18mm. |
NDB1LE-40Z/63Z |
Residual current action MCB with self-diagnostics |
NDB1Z-63 |
Direct current MCB |
NDB1LE-63X(G) |
Residual current action MCB in small size |
NDB1TS-63 |
Single Magnetic Miniature Circuit Breakers, Icu= 6kA |
NDB2 |
NDB2-40/63(H) |
For full range of 63 shell frame,Icu=10kA(High breaking Type H up to 15kA); For full range of 40 shell frame,Icu=6kA. |
NDB2NZ-80H |
High voltage DC1000V, small size |
NDB2N-125A |
Both AC and DC are optional,4.5kA for AC and 10KA for DC. |
NDB2T-63(UL489) |
Comply with GB14048.2 standard, UL489 certification are optional. |
NDB2LE-32/40/63 |
The width of 32 shell frame is only 18mm; MCB for 32 and 40 shell frame are optional in A and AC types;For full range of 63 shell frame,Icu=10kA. |
NDB2LM-63/40 |
Electromagnetic leakage, strong anti-interference ability |
NDB2F-125W |
MCB of energy meter extraposition. |
NDB2Z-63 |
DC MCB; Maximum Operating Voltage: DC1000V |
NDB2ZB-63 |
DC three-section MCB |
NDB2TS-63 |
Single Magnetic Miniature Circuit Breakers, Icu= 10kA |
NDL2M-100 |
Electromagnetic leakage protector without overcurrent protection function. |
NDB6 |
NDB6-125 |
High breaking,Icu=15kA |
NDB6Z-125 |
DC MCB with breaking capacity up to 15kA |
NDL6M-100 |
Electromagnetic leakage protection device, without overcurrent protection function
|
NDB6LM-40 |
Electromagnetic miniature circuit breakers with leakage protection, are optional in both A and AC type;Breaking capacity up to 10 KA. |
NDB6A(Z) |
5G-specific circuit breaker with a height of only 1U |
NDB5E |
NDB5E-40/80 |
Intelligent MCB, with power metering, remote switching, internal temperature monitoring and other functions, need to be used with the power module and communication module together. |
NDB5EL-40/80 |
Leakage protection type intelligent micro-break, with power metering, remote switching, internal temperature monitoring and other functions; leakage module is installed at the lower end, reducing space. |
NDB5E-80X |
One-piece intelligent micro-break; power module, electrical operation module, gateway module three in one, three in one module width of 18mm;Used with 1P & 2P body. |
Power Module |
Power supply output power of 12W, a power supply module can take up to 10 circuit breakers. |
Gateway Module |
Equipped with communication modules such as WIFI+RS485, RS485, 4G, NB, ETH, etc. |
2.Indoor Box
 |
 |
 |
NDP1A Series Distribution Box |
NDP3A Series Distribution Box |
NDP3T Series Distribution Box |
Series |
Design Series |
Product Features |
NDP1A |
NDP1A |
Plastic top cover, single row, double row, up to 40 positions |
NDP3A |
NDP3A |
Plastic top cover, single row, double row, triplex row,up to 45 positions |
NDP3T |
NDP3T |
Metal cover, single row, double row, up to 40 positions |
3.SPD(Surge Protective Device)
 |
 |
NDU1 Series Surge Protective Device |
NDU1Z Series Surge Protective Device |
Series |
Design Series |
Product Features |
NDU1 |
NDU1 |
Class Ⅱ surge, maximum current up to 120kA |
NDU1-I |
NDU1-I |
ClassⅠsurge, imp current up to 120kA |
NDU1Z |
NDU1Z |
DC surge, Ⅰmax = 40kA, maximum operating voltage DC1000V |
4.Surge Backup Protection Circuit Breakers
 |
NDUH1 Series Surge Protective Device |
Series |
Design Series |
Product Features |
NDUH1 |
NDUH1 |
For protection of voltage-limited low-voltage surge protective device |
5.Modular Sockets
 |
NDA1Series Sockets |
Series |
Design Series |
Product Features |
NDA1 |
NDA1 |
For protection of voltage-limited low-voltage surge protective device |
6.Oil Damping Products
 |
 |
NDB3-125 Series |
NDB Series |
Series |
Design Series |
Product Features |
NDB3 |
NDB3 |
Hydraulic/oil damping circuit breakers used in communication power supplies and industrial control systems |
NDB5 |
NDB5 |
Hydraulic/oil damping circuit breakers used in communication power supplies and industrial control systems |
7.Busbar
 |
NDH1 Busbar |
Series |
Design Series |
Product Features |
NDH1/H2 |
NDH1/H2 |
Connection of multiple circuit breakers with the same phase feeder end |
8.Dual Power Products
 |
 |
 |
NDQ1 Series Automatic Transfer Switches |
NDQ2A Series Automatic Transfer Switches |
NDQ5 Series Automatic Transfer Switches |
Series |
Design Series |
Product Features |
NDQ1 |
NDQ1-63/125/250/400/630/800 |
Molded Case Circuit Breaker Derived Dual Power, Class CB, Motor Driven, 3-Stage. |
NDQ2 |
NDQ2A-63/125H/250 |
NDQ2A-63:Miniature Circuit Breaker Derivative Dual Power, Class CB, Motor Driven, 3-Stage |
NDQ2A-63/125H/250 |
NDQ2A-125H:Compact Disconnect Switch Derived PC Class Dual Power Supply, Motor Driven, 3-Stage |
NDQ2A-63/125H/250 |
NDQ2A-250: PC-class dual power supplies, Motor Driven, 3-stage |
NDQ3 |
NDQ3-125/250/400/630/800
/1250/1600/2000 |
PC-class dual power supplies, solenoid drive, two or three-stage are optional. |
NDQ3H |
NDQ3H-63/125/250/400/630
/800/1250/3150/5000 |
PC-class dual power supplies, four controllers (1250A above only D-type optional), solenoid drive, two or three-stage(1250A above only two sections), can realize the communication function, 125 ~ 800A five shell frame optional neutral line overlap conversion function. |
NDQ3H |
NDQ3H-4000 |
PC-class dual power supplies, three-section, with neutral overlap conversion, use category AC-33A. |
NDQ3HP |
NDQ3HP-3200/5000 |
Dedicated PC-class dual power supplies, two- or three-section type, with bypass isolation and neutral line overlap conversion, used with category AC-33A. |
NDQ5W |
NDQ5W-1600/2500/4000 |
Frame Circuit Breaker Derived CB Class Dual Power, High Breaking, Dual Power/ Triple Power Switching, Two Incoming Wires and One Female Connection, Parallel Switching optional |
NDQ5 |
NDQ5-4000 |
Dedicated PC-class dual power supplies, three -section, with neutral line overlap conversion function, parallel switching, used with category AC-33A |
9.Disconnect Switch Products
 |
 |
 |
NDGR2 Series Disconnect Switch Fuse Block |
NDG3V-32/50 Series Disconnect Switch Fuse Block |
NDG3V-50H F Remote release disconnect switches |
Series |
Design Series |
Product Features |
NDG1 |
NDG1-100/125 |
Modular Miniature Disconnect Switches |
|
NDGR2-63/125/160/250/400/630/800/1000/1250 |
Disconnect Switch Fuse Block |
NDGP2 |
NDGP2-2000/2500 |
Large format load isolation |
NDG3V |
NDG3V-32/50 |
Dedicated for photovoltaic, rotary double-breakpoint, AC/DC disconnect switches, up to DC1500V/AC415V (32 shell frame) /AC690(50 shell frame) |
NDG3 |
NDG3-100/125/100H/125H/160H/200/250/160/315/400/500/630/800/1000/1250 |
Load isolation switch, small size, maximum voltage DC1000V or AC1000V, maximum current 2000A |
NDG3V |
NDG3V-250/350/4001500/630/800 |
DC disconnect switch, max. Voltage: DC1500V, max. Current: 800A |
NDG3V |
NDG3V-50H F |
Remote release disconnect switches, high breaking capacity DC1500V with 2 levels of wiring up to 40A |
NDG3VH |
NDG3VH-100-630 |
DC1500V and below, rated operating current 630A and below |
NDG3A |
NDG3A-1000Z/1600Z/
2000Z/2500Z/3200Z |
Isolator, maximum rated voltage DC1500V, maximum current 3200A |
10.ACB(Air Circuit Breaker)
 |
 |
 |
NDW1A Series Air Circuit Breaker |
NDW2X Series Air Circuit Breaker |
NDW3X-4000 Offshore wind power type universal circuit breaker |
Series |
Design Series |
Product Features |
NDW1A |
NDWV1A-1600/200013200/4000/6300 |
Suitable for civil buildings and other fields, breaking capacity up to 120KA |
NDW2
|
NDW2-1600/2000/3200/4000/6300 |
Suitable for industrial buildings and other fields, rated working voltage up to AC1140V (NDW2-4000HU/6300HU) |
NDW2G-2000/4000 |
Framed Disconnect Switches |
NDW2GZ-2000/4000 |
Framed disconnect switches optional for DC systems |
NDW2F-2000/3200/4000 |
Dedicated frame circuit breakers for power generation systems |
NDW3 |
NDW3-1600/2500/4000/6300/7500 |
Ics=100%lcu=100%cw,Maximum operating voltage: AC1500V (NDW3-2500XU/4000XU/6300XU) |
NDW3Z-2500/4000 |
Frame circuit breakers for DC systems, rated current 800-4000A, rated operating voltage up to DC1500V |
NDW3B-3200 |
Newly designed shape and structure |
NDW3AGZ-2500 |
DC Type Disconnect Switches |
NDW3A-2500 |
Comply with UL1066 standard, high voltage: AC730V. |
11.MCCB(Molded Case Circuit Breaker)
 |
 |
 |
NDM2 Series Molded Case Circuit Breaker |
NDM5G(Z)-1600 Plastic enclosure disconnect switches |
NDMNZ Series DC Molded Case Circuit Breakers |
Series |
Design Series |
Product Features |
NDM2 |
NDM2-63/125/250/400/630/800(NDM2X-125) |
Complete shell frame, widely used in civil construction and other fields |
NDM2E-100/250/400/630/800 |
Electronic molded case circuit breaker, 3-pole H-type, can realize three (four) stages of protection, can be optional grounding function, communication and other functions |
NDM2Z-63/125/250/400/630(NDM2ZX-125) |
DC Molded Case Circuit Breakers,Ue=DC250V |
NDM2ZB-63/125/250/400/630/800 |
DC three-stage protection function can be realized. Ue=250vIcs=100%lcu |
NDM2L-125/250/400/630 |
Moulded case circuit breaker with leakage protection, leakage current/delay time adjustable, leakage one-piece design, smaller size;for 630 shell frame leakage current V/W type are optional. |
NDM3 |
NDM3-63/100/125/160/400/630/800/1600 |
Thermal magnetic molded case circuit breaker, double insulation face cover design; optional overload alarm without release function |
NDM3E-1251250/400630/800(NDM3FX -1600) |
Electronic molded case circuit breaker, three-section (four-section) protection; 3-pole (M/H-type breaking optional)/ 4-pole are optional; grounding, communications and other functions are optional. |
NDM3E(IOT)-250/400/630 |
With automatic identification of distribution network topology and power line carrier communication function |
NDM3G-250/250V1400/400V/630/800 |
Plastic-case derived disconnect switches, AC1140V/DC1000V. |
NDM3A-250/400/630 |
High voltage, Ue up to AC1000V |
NDM3AR-125/250/400/630 |
Thermal Magnetic Moulded Case Circuit Breakers, Thermal Magnetic Adjustable |
NDM3L-125/250/400/630/800 |
Adjustable leakage current and delay time |
NDM3Z-125/250/250V/250VM/320V/400/630/630V/800 |
DC molded case circuit breakers, Ue up to DC1500V |
NDM3ZB-125/250/400/800 |
DC three-stage protection, Ue=250V, M/H type breaking capacity are optional |
NDM3DLC-250/400/630 |
IOT leakage reclosing circuit breaker with three-stage protection, leakage protection and HPLC+RS485 communication function |
NDM5 |
NDM5-12511601250/250V1400/400V1630/630V11600 |
High breaking, rotating double break, thermomagnetically adjustable |
NDM5E-125/160/250/400/630/1600 |
High breaking, L/M/H type are optional.Ics=100%lcu |
NDM5Z-160/250/400/630/1600 |
Rated operating voltage up to DC1500V, high breaking, Ics=100%lcu |
NDM5G-400V/1600 |
Derived molded Disconnect Switches, Rated operating voltage up to AC1140V or DC1500V. |
NDM5GZ-1600 |
Derived molded Disconnect Switches, Rated operating voltage up to DC1500V. |
12.Industrial Control Products
 |
 |
 |
NDC1(Z)-09~95 Series Alternating Current Contactors |
NDC1N-115~800Series Reversible Alternating Current Contactors |
NDC2-150RX~750RX Series Alternating Current Contactors |
Series |
Design Series |
Products Characters |
NDC1 |
NDC1-09~95、115- 2650 |
Alternating Current Contactors (NDC1(Z): AC contactors for DC operation; NDC1N: reversible contactors) |
NDC1M |
NDC1M-09~95、115-2650 |
AC contactors dedicated for large buildings. |
NDC1T |
NDC1T-40~65 |
Dustproof AC contactors, boltable wiring, protection level: IP50. |
NDC2 |
NDC2-06~170 |
AC contactors (NDC2N:reversible contactors) |
NDC2J |
NDC2J-16~63 |
Digitally modeled AC contactors for installing in indoor boxes |
NDC2 |
NDC2-80R~750R |
AC contactors dedicated for AC-1 |
NDC3 |
NDC3-09~95 |
AC contactors, high life span (NDC3(Z、ZE): AC contactors for DC operation; NDC3N: reversible contactors) |
NDC5K |
NDC5K-630~3200 |
Vacuum AC Contactors, Zero Flying Arc |
NDD1 |
NDD1-1~80 |
Motor protection circuit breaker, overload, short circuit, three-phase unbalance protection |
NDY1 |
NDY1-20~160 |
Changeover switches, manual infrequent switching and breaking of circuits |
NDK1 |
NDK1-25~125 |
Switching capacitor contactors for controlling capacitor switching |
NDJ1/NDJ3 |
NDJ1(Z)/NDJ3(ZE) |
Contactor-type relays, control solenoids, for signal amplification or transmission (NDJ1Z/NDJ3ZE:DC operation) |
NDCQ1 |
NDCQ1-12~95 |
Star Delta Starter |
NDR1E |
NDR1E/2 |
NDR1E: electronic thermal relay; NDR2: double gold thermal relay, which can Plug and run with NDC1 series products directly. |
NDR3E |
NDR3E |
Electronic overload relays and can be used with NDC3 series contactors |
NDKB1/NDKB3 |
NDKB1-45~125 NDKB3-63 |
Control and protection switching appliances with operating voltage up to AC 690V |
NDJG3 |
NDJG3-25~40 |
Hybrid Relays |
13.DC Contactors(Direct Current Contactors)
Series |
Design Series |
Products Characters |
NDZ3 |
NDZ3(X/W)-50~300 |
Epoxy encapsulated DC contactors |
NDZ3X |
NDZ3X-10~40 |
Epoxy encapsulated DC contactors |
NDZ3T/AT |
NDZ3T/AT-10~400 |
Ceramic encapsulated DC contactors with operating voltage up to DC750V |
NDZ3AT |
NDZ3AT-100D,150D |
Ceramic package, operating voltage DC12~1000V |
NDZ3AT |
NDZ3AT-150G,200G |
Ceramic package, operating voltage DC12~1000V |
NDZ3AT |
NDZ3AT-25010H~60010H |
Ceramic package, operating voltage DC12~1500V |
NDZ3AT |
NDZ3AT-150R~350R |
Ceramic package, operating voltage DC12~1000V |
14.Intelligent Cabinet
 |
 |
NEA Series Low Voltage Switchgear |
NEA E Series Intelligent Power Distribution Box |
Series |
Design Series |
NEA |
NEA Intelligent Power Distribution Cabinet |
NEA E |
NEA E Intelligent Power Distribution Case |
15.Conclusion
Nader’s product ecosystem demonstrates remarkable depth and specialization across key domains of low-voltage power distribution and control. From the versatile NDB1 and NDM series of circuit breakers to intelligent energy solutions such as NDB5E and NEA cabinets, Nader provides a full-spectrum portfolio that supports residential, commercial, and industrial applications. The inclusion of DC contactors, intelligent modules, and surge protection devices highlights the brand’s adaptation to evolving power infrastructures, including renewable energy and smart grid demands. With standardized form factors, modular designs, and compliance with major international certifications (e.g., UL, GB, IEC), Nader’s offerings aim to balance reliability, safety, and innovation. This document serves as both a technical reference and a roadmap for understanding how Nader’s solutions integrate into modern power systems.