  • 【Technology】 The difference between the rated current of the circuit breaker and the rated current of the release
    Updated 09/09/2020
    1n rated current circuit breaker, refers to long-term through the current release, which is the rated current release. Maximum release was breaker trip unit with adjustable by the long term. Rated current 1n, refers to the maximum current release by the long-term. Long delay overload release operatin...
    Tags: rated currenttrip unitcurrent
  • 【Technology】 The working principle and selection of thermal relay
    Updated 09/09/2020
    Thermal relay works heat is generated by the current flowing into the heating element, so that the bimetal has different coefficients of expansion is deformed when the deformation reaches a certain distance, the operation to push link, so that the control circuit is opened, so that the contact loss o...
    Tags: relayelectric motor
  • 【Technology】 3 reasons for the accidental tripping of circuit breakers
    Updated 09/09/2020
    The main reason for Ontripping: misoperation, the trip actuator itself, the electrical secondary circuit. 1. When Ontripping, should first check whether staff misuse. Staff misuse There are two cases: one is a mistake; the second is on the way back due to improper protection safeguards and causing ma...
    Tags: trip
  • 【Technology】 Handling guide for circuit breaker refusal to close
    Updated 09/09/2020
    Refused fault breaker closing process, must be able to distinguish between fault coverage, the process steps: bonding a first determines whether or not the circuit breaker due to the fault line Yufu trip meter indication may be caused by the presence or absence of short-circuit current closing operat...
    Tags: refused to close
  • 【Technology】 Precautions for installation and use of low-voltage circuit breakers
    Updated 09/09/2020
    Predetermined low voltage circuit breaker should be mounted vertically, which, at a predetermined connecting wire for use in wire cross section (or bus), must not be too small. Low voltage circuit breaker trip unit setting current parameters and other features and selection of parameters, a good tone...
    Tags: low-voltage circuit breakerleakage protection switch
  • First
  • Prev
  • 28
  • 29
  • 30
  • Next
  • Last
  • Products
    ACB
    MCCB
    ATS
    MCB
    HMCB
    Blog
    Company
    Industry
    FAQs
    Technology
    About Nader
    R&D Platform
    Quality Platform
    Manufacturing
    Address:No.2000, South ShenJiang Road, Pudong New Area
    Tel:+86-21-68586719
    Email:rfq@nader-circuit-breaker.com