Home / Blog / Technology /
  • 【Technology】 Main parameters of high voltage circuit breaker
    Updated 09/09/2020
    1. Rated voltage Rated voltage refers to the voltage level that the high-voltage circuit breaker can withstand during normal operation, and it determines the insulation level of the circuit breaker. The rated voltage (UN) refers to its line voltage. The rated voltage levels of commonly used circuit b...
    Tags: high voltage circuit breaker
  • 【Technology】 Definition and classification of low-voltage circuit breakers
    Updated 09/09/2020
    Section Overview First, the definition of low-voltage circuit breakers, and perform standard classifications (a) is defined using a low voltage circuit breaker for low voltage power [AC (50Hz or 60Hz rated voltage and below 120, and the DC rated voltage of 1200v .] below the electrical power distribu...
    Tags: low-voltage circuit breakerscircuit breaker classification
  • 【Technology】 Use and classification of low-voltage circuit breakers
    Updated 09/09/2020
    Circuit Breakers commonly known as automatic air switch. Low voltage distribution network is one of the main switching device, the low pressure switch is a switch best performance. It can be used to turn on, breaking the normal load current, and has a function of automatic protection circuit. When th...
    Tags: low-voltage circuit breakerstrip unitsdelay switcheselectric motors
  • 【Technology】 11 operating points in the use of circuit breakers
    Updated 09/09/2020
    Formed into universal type (frame type) and a type molded case (device type) of two kinds of low voltage circuit breaker according to the structure. Breaker its structure is compact, reliable, safe, etc., in all types of building construction site as electrical distribution systems, cables, motors an...
    Tags: circuit breaker maintenance
  • 【Technology】 Specification requirements and methods for circuit breaker selection
    Updated 09/09/2020
    Short-circuit breaker breaking capacity ≥ lines prospective short circuit current. Suppose a power supply (SL7 10 / 0.4kV transformer) capacity of 1600kVA, the secondary current of 2312A, short-circuit current which is at the outlet end of 5m 42.96kA. Is a rated current branch 125A, since this leg ...
    Tags: short-circuit currenttrip unitbreaking capacityshort-circuit capacity
  • First
  • Prev
  • 27
  • 28
  • 29
  • Next
  • Last
  • Products
    ACB
    MCCB
    ATS
    MCB
    HMCB
    Blog
    Company
    Industry
    FAQs
    Technology
    About Nader
    R&D Platform
    Quality Platform
    Manufacturing
    Address:No.2000, South ShenJiang Road, Pudong New Area
    Tel:+86-21-68586719
    Email:rfq@nader-circuit-breaker.com